Roll over image to zoom in
Cardiac Multifunction Patient Monitor Price in Bangladesh
৳ 55,000৳ 65,000 (-15%)
Specification:
Brand: YK-8000G
Weight: 8.8 lb
Working Capability: 2-hour
Size: 12 * 11.4 * 6.4 inch
Alarms: 3-level audio/visual
Battery: Built-in rechargeable lithium battery
Display: 12.1-inch high-resolution color TET LCD
Standard configuration: SpO2, PR, NIBP, ECG, RESP, TEMP
Description
Medical stall provides the best quality patient monitor price in BD, Cardiac Monitor at a cheap price in BD Call us to purchase our product 01717-661190. Multifunction cardiac patient monitor, ECG / NIBP / SPO2 / TEMP / RESP function, 12″ TFT LCD, suitable for bed side, built-in detachable rechargeable lithium battery, 2.5 to 3 hours stand by time, made in China.
ECG
Band width: 0.05Hz-100Hz(3dB)
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
SpO2
±2% 70%-89%
Accuracy: ±1% 90%-100%
Detection scope: 0%-100%
Temp
Scope: 20℃~50℃
Accuracy: ±0.2℃
Single/double path
Type: Vascular/surface temperature
Invasive blood pressure (optional)
Single/double path
Pa(100mmHg) above ±2%
Motivation voltage:5V (DC)
Frequency response:DC-12Hz
Sensitivity of sensor: 5μV/V/mmHg
Input resistance: not less than 500kΩ
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Accuracy of sensor: ±2%Isolation voltage: 4 kV
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33k
NIBP
Pulse rate: ±2%
Static pressure: ±3mmHg
Theory Electric oscillator
in -90min) and 30min(90 min -240min)
Cuff gassing time less than 15 seconds
Automatic detection period: 1 minute to 240 minutes
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
Detection scope:
Detection accuracy
Mean pressure: 2.7kPa~31.3kPa: (20mmHg~235mmHg
Diastolic pressure: 2kPa -29.3kPa(15mmHg -220mmHg)
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Resp
The precision of chest impedance method time/minute
Detection precision of respiration rate: ±1 time/minute
Scope of chest impedance method 0 time/minute – 100 minutes/minute
Chest impedance method or concentration of carbon dioxide at end of respiration
Detection scope of carbon-oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute including baby)
Heart rate:
ST: section
Scope: ±0.8mV
Undetected rate < 20%
Precision: < ±0.05mV
Accuracy: ±1 time/minute
Accuracy: Error rate < 20%
Scope: 15 times/minute to 300 times/minutes
Variation of heartbeat LORENZO drawing: Analysis on heartbeat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.